Indication based vs anatomical region based diagnostic reference levels
DOI:
https://doi.org/10.55378/rv.47.2.8Keywords:
DRL, typical values, CT, diagnostic reference levels, optimisationAbstract
The use of diagnostic reference levels in daily clinical practice with the aim of optimising the procedures performed with X-ray devices for computed tomography can be challenging if they are given for specific anatomical regions. The reason for this is the fact that different protocols can be used for imaging the same anatomical region, depending on the required level of image quality, which is determined by the clinical indication. Comparison of typical values of dosimetric quantities with such diagnostic reference levels can be misleading with regard to the need for taking corrective measures either with the aim of reducing patient exposure or with the aim of improving the quality of diagnostic information. For this reason, it is important to establish and use diagnostic reference levels that are given for a particular clinical indication, which will be shown in this paper on several examples from everyday clinical practice.
References
IAEA. Specific Safety Guide No. SSG-46: Radiation Protection and Safety in Medical Uses of Ionizing Radiation. Vienna; 2018.
ICRP. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publ 103. 2007;ICRP 37(2–4).
Ministarstvo unutarnjih poslova. Pravilnik o uvjetima za primjenu izvora ionizirajućeg zračenja u svrhu medicinskog i nemedicinskog ozračenja. Nar novine 42/18, 8/22. 2022;
Kralik I, Buinac A, Justic M, Ružić K, Faj D. DRL – alat u službi optimizacije provedbe dijagnostičkih i intervencijskih postupaka. Radiološki Vjesn [Internet]. 2021 [cited 2023 Jan 3];2:16–9. Available from: https://hdrt.hr/radioloski-vjesnik/rv-2021-2/drl-alat-u-sluzbi-optimizacije-provedbe-dijagnostickih-i-intervencijskih-postupaka
ICRP. Diagnostic reference levels in medical imaging. ICRP Publ 135. 2017;46(1).
European Commission. European Study on Clinical Diagnostic Reference Levels for X-ray Medical Imaging. Radiat Prot Publ 195. 2021;
Paulo G, Damilakis J, Tsapaki V, Schegerer AA, Repussard J, Jaschke W, et al. Diagnostic Reference Levels based on clinical indications in computed tomography: a literature review. Insights Imaging [Internet]. 2020;11(1):96. Available from: https://doi.org/10.1186/s13244-020-00899-y
Comparison of typical doses for ten CT clinical indications with EU clinical DRLs in three Croatian university hospitals. 2023 [cited 2023 Sep 3]; Available from: https://epos.myesr.org/poster/esr/eurosafeimaging2023/ESI-16947
European Commission. European guidelines on diagnostic reference levels for paediatric imaging. Radiat Prot Publ 185. 2016;
Downloads
Published
Issue
Section
Categories
License
Copyright (c) 2023 Ivana Kralik, Tajana Turk, Katarina Ružić, Jelena Popić, Dajana Meštrić, Mihaela Justić, Danijel Cvetko, Ana Buinac, Ivana Bjelobrk, Dario Faj (Autor)

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
CART