Automatizirani pregled dojke ultrazvukom

Autor(i)

  • Marija Žaja University of Split, University Department of Health Studies, Split, Croatia Autor
  • Tatjana Matijaš University of Split, University Department of Health Studies, Split, Croatia Autor

DOI:

https://doi.org/10.55378/rv.46.2.2

Ključne riječi:

ABUS, CAD, mamografija, probir, rak dojke

Sažetak

Zbog sve većeg broja oboljelih od raka dojke, a kako bi se smanjila smrtnost, vrlo je važna rana dijagnostika. U dijagnostici raka dojke koriste se metode kao što su mamografija, DBT, MRI, HHUS ili ABUS. Cilj ovoga rada je bio pregledom literature prikazati princip rada ABUS-a te ukazati na njegove prednosti i nedostatke u odnosu na konvencionalne metode snimanja dojki. ABUS je relativno nova ultrazvučna metoda koja je pokazala izvrsne rezultate kod žena s gustim grudima. Korištenje ABUS-a smanjuje ovisnost o operateru, a omogućuje vrijedne dijagnostičke informacije s multiplanarnim rekonstrukcijama. Pregledom brojnih istraživanja u ovom radu, ABUS se pokazao kao značajno osjetljivija metoda sa boljom stopom otkrivanja raka dojke u odnosu na zlatni standard, mamografiju. Korištenje ovih dviju metoda zajedno u probiru pokazalo je izvrsne rezultate koji potvrđuju važnost implementacije u kliničku praksu. Nedostatak kombinacije ABUS-a i mamografije je bio taj što je u velikom broju studija specifičnost bila niža u odnosu na samu mamografiju. U odnosu na DBT, ABUS je pokazao superiornije rezultate, osim u detekciji kalcifikacija. Iako je ABUS pokazao nešto lošije rezultate u usporedbi s MRI-om, jednostavnost uporabe i niska cijena čine ga alternativom MRI-u. Što se pak HHUS-a tiče, kao njegovu prednost u odnosu na ABUS pacijentice su navele manje bolan pregled i kraće trajanje, iako se on pokazao manje osjetljivijim i specifičnijim u odnosu na ABUS. Korištenje umjetne inteligencije danas postaje svakodnevnica, pa su tako razvijeni i posebni CAD softveri za ABUS kojima je svrha poboljšati stopu otkrivanja raka dojke i točnost radiologa. Korištenje CAD-a značajno je smanjilo vrijeme očitavanja slika te poboljšalo dijagnostičku točnost ABUS-a. Prema svim iznesenim podatcima, važnost ABUS uređaja u kliničkoj praksi je iznimno velika, a daljnim razvojem tehnologije i medicine, očekuje se njegova potpuna integracija u zdravstvene sustave diljem svijeta.

Reference

ˮBreast cancerˮ [Internet]. World Health Organization, 26 March 2021, [accessed: 13.5.2022].

Available at: https://www.who.int/news-room/fact-sheets/detail/breast-cancer

ˮIncidencija i mortalitet od raka u EU-27 zemljama za 2020. godinuˮ [Internet]. Hzjz.hr, 3. rujna 2020, [accessed: 13.5.2022].

Available at: https://www.hzjz.hr/sluzba-epidemiologija-prevencija-nezaraznih- bolesti/incidencija-i-mortalitet-od-raka-u-eu-27-zemljama-za-2020-godinu/

Radović, N. Utjecaj radioterapije na vrijednost očiglednoga koeficijenta difuzije zdravoga tkiva i lezija dojke pri oslikavanju magnetskom rezonancijom. [Internet]. Zagreb, Sveučilište u Zagrebu, Medicinski fakultet; 2020, [accessed: 13.5.2022].

Available at: https://repozitorij.mef.unizg.hr/islandora/object/mef:2929

ˮRak dojkeˮ [Internet]. Hlpr.hr, [accessed: 13.5.2022].

Available at: https://hlpr.hr/rak/vijest/rak-dojke

ˮNacionalni programi ranog otkrivanja rakaˮ [Internet]. Hzjz.hr, 22. prosinca 2016, [accessed: 13.5.2022].

Available at: https://www.hzjz.hr/sluzba-epidemiologija-prevencija-nezaraznih-%20bolesti/preventivni-program-za-zdravlje-danas/#rak-dojke

Poljičak, D. Radiološka dijagnostika bolesti dojke. [Internet]. Split, Sveučilište u Splitu, Sveučilišni odjel zdravstvenih studija; 2018, [accessed: 13.5.2022].

Available at: https://repo.ozs.unist.hr/islandora/object/ozs:705

Zanotel M, Bednarova I, Londero V, Linda A, Lorenzon M, Girometti R, et al. Automated breast ultrasound: basic principles and emerging clinical applications. Radiol Med. 2018 Jan;123(1):1-12.

Boca Bene I, Ciurea AI, Ciortea CA, Dudea SM. Pros and Cons for Automated Breast Ultrasound (ABUS): A Narrative Review. J Pers Med. 2021 Jul 23;11(8):703.

ˮFDA Clears somo•V Automated Breast Ultrasound (ABUS) Systemˮ [Internet]. Itnonline.com, 2012, [accessed: 22.5.20022]

Available at: https://www.itnonline.com/content/fda-clears-somo%E2%80%A2v-automated- breast-ultrasound-abus-system

Jia M, Lin X, Zhou X, Yan H, Chen Y, Liu P, et al. Diagnostic performance of automated breast ultrasound and handheld ultrasound in women with dense breasts. Breast Cancer Res Treat. 2020 Jun;181(3):589-597.

Nicosia L, Ferrari F, Bozzini AC, Latronico A, Trentin C, Meneghetti L, et al. Automatic breast ultrasound: state of the art and future perspectives. Ecancermedicalscience. 2020 Jun 23;14:1062.

ˮInveniaTM ABUS 2.0ˮ [Internet]. Ge-ultrasound.eu, [accessed: 22.5.2022]

Available at: https://ge-ultrasound.eu/voluson-gynecology-obstetrics/invenia-abus-2-%200/?gclid=CjwKCAiAg6yRBhBNEiwAeVyL0FcadAUlZ8rYLQIdMWhnI3qWz%20SCM0GVksIGOm7PKisANiodgLFyROBoCcp4QAvD_BwE

Mostafa AAE, Eltomey MA, Elaggan AM, Hashish AA. Automated breast ultrasound (ABUS) as a screening tool: initial experience. Egypt J Radiol Nucl Med. 2019;50, 37

Elkhalek YI, Bassiouny AM, Hamid RWARA. Automated breast ultrasound system (ABUS): can it replace mammography as a screening tool?. Egypt J Radiol Nucl Med. 2019;50, 51

Xin Y, Zhang X, Yang Y, Chen Y, Wang Y, Zhou X, Qiao Y. A multicenter, hospital-based and non-inferiority study for diagnostic efficacy of automated whole breast ultrasound for breast cancer in China. Sci Rep. 2021 Jul 6;11(1):13902

Hadadi I, Rae W, Clarke J, McEntee M, Ekpo E. Diagnostic Performance of Adjunctive Imaging Modalities Compared to Mammography Alone in Women with Non-Dense and Dense Breasts: A Systematic Review and Meta-Analysis. Clin Breast Cancer. 2021 Aug;21(4):278-291.

Giger ML, Inciardi MF, Edwards A, Papaioannou J, Drukker K, Jiang Y, et al. Automated Breast Ultrasound in Breast Cancer Screening of Women With Dense Breasts: Reader Study of Mammography-Negative and Mammography-Positive Cancers. AJR Am J Roentgenol. 2016 Jun;206(6):1341-50.

Wilczek B, Wilczek HE, Rasouliyan L, Leifland K. Adding 3D automated breast ultrasound to mammography screening in women with heterogeneously and extremely dense breasts: Report from a hospital-based, high-volume, single- center breast cancer screening program. Eur J Radiol. 2016 Sep;85(9):1554-63.

Gatta G, Cappabianca S, La Forgia D, Massafra R, Fanizzi A, Cuccurullo V, et al. Second-Generation 3D Automated Breast Ultrasonography (Prone ABUS) for Dense Breast Cancer Screening Integrated to Mammography: Effectiveness, Performance and Detection Rates. J Pers Med. 2021 Aug 31;11(9):875.

Zintsmaster S, Morrison J, Sharman S, Shah BA. Differences in Pain Perceptions between Automated Breast Ultrasound and Digital Screening Mammography. Journal of Diagnostic Medical Sonography. 2013;29(2):62-65.

Hashem LMB, Ali RHM, Helal MH, Gemeae EL, Moustafa AFI. Characterization of breast masses: a comparative study between automated breast ultrasound (ABUS) and digital breast tomosynthesis (DBT). Egypt J Radiol Nucl Med. 2020 Mar;51, 47

ˮABUS better than DBT for diagnostic workupˮ [Internet] Auntminnie.com, 2019, [accessed: 7.6.2022]

Available at: https://www.auntminnie.com/index.aspx?sec=404&sub=def

Schäfgen B, Juskic M, Radicke M, Hertel M, Barr R, Pfob A, et al. Evaluation of the FUSION-X-US-II prototype to combine automated breast ultrasound and tomosynthesis. Eur Radiol. 2021 Jun;31(6):3712-3720.

ˮFinal Report Summary – ASSURE (Adapting Breast Cancer Screening Strategy Using Personalised Risk Estimation)ˮ [Internet] Cordis.europa.eu, 2016, [accessed: 7.6.2022]

Available at: https://cordis.europa.eu/project/id/306088/reporting

Obdeijn IM, Winter-Warnars GA, Mann RM, Hooning MJ, Hunink MG, Tilanus- Linthorst MM. Should we screen BRCA1 mutation carriers only with MRI? A multicenter study. Breast Cancer Res Treat. 2014 Apr;144(3):577-82.

Obdeijn IM, Mann RM, Loo CCE, Lobbes M, Voormolen EMC, van Deurzen CHM, et al. The supplemental value of mammographic screening over breast MRI alone in BRCA2 mutation carriers. Breast Cancer Res Treat. 2020 Jun;181(3):581-588.

Giuliano V, Giuliano C. Using Automated Breast Sonography as Part of a Multimodality Approach to Dense Breast Screening. Journal of Diagnostic Medical Sonography. 2012;28(4):159-165.

Schmachtenberg C, Fischer T, Hamm B, Bick U. Diagnostic Performance of Automated Breast Volume Scanning (ABVS) Compared to Handheld Ultrasonography With Breast MRI as the Gold Standard. Acad Radiol. 2017 Aug;24(8):954-961.

Girometti R, Zanotel M, Londero V, Linda A, Lorenzon M, Zuiani C. Automated breast volume scanner (ABVS) in assessing breast cancer size: A comparison with conventional ultrasound and magnetic resonance imaging. Eur Radiol. 2018 Mar;28(3):1000-1008.

Kim SH, Kim HH, Moon WK. Automated Breast Ultrasound Screening for Dense Breasts. Korean J Radiol. 2020 Jan;21(1):15-24.

Zhang X, Chen J, Zhou Y, Mao F, Lin Y, Shen S, et al.. Diagnostic value of an automated breast volume scanner compared with a hand-held ultrasound: a metaanalysis. Gland Surg. 2019 Dec;8(6):698-711.

Yun G, Kim SM, Yun B, Ahn HS, Jang M. Reliability of automated versus handheld breast ultrasound examinations of suspicious breast masses. Ultrasonography. 2019 Jul;38(3):264-271.

Chen H, Han M, Jing H, Liu Z, Shang H, Wang Q, et al. Dependability of Automated Breast Ultrasound (ABUS) in Assessing Breast Imaging Reporting and Data System (BI-RADS) Category and Size of Malignant Breast Lesions Compared with Handheld Ultrasound (HHUS) and Mammography (MG). Int J Gen Med. 2021 Dec 1;14:9193-9202.

Jeh SK, Kim SH, Choi JJ, Jung SS, Choe BJ, Park S, et al. Comparison of automated breast ultrasonography to handheld ultrasonography in detecting and diagnosing breast lesions. Acta Radiol. 2016 Feb;57(2):162-9.

Allajbeu I, Hickman S, Payne N, Moyle P, Taylor K, Sharma N, et al. Automated Breast Ultrasound: Technical Aspects, Impact on Breast Screening, and Future Perspectives. Current Breast Cancer Reports. 2021 Jun;13(3):141-150.

Tutar B, Esen Icten G, Guldogan N, Kara H, Arıkan AE, Tutar O, et al. Comparison of automated versus hand-held breast US in supplemental screening in asymptomatic women with dense breasts: is there a difference regarding woman preference, lesion detection and lesion characterization? Arch Gynecol Obstet. 2020 May;301(5):1257-1265.

Brunetti N, De Giorgis S, Zawaideh J, Rossi F, Calabrese M, Tagliafico AS. Comparison between execution and reading time of 3D ABUS versus HHUS. Radiol Med. 2020 Dec;125(12):1243-1248.

Mussetto I, Gristina L, Schiaffino S, Tosto S, Raviola E, Calabrese M. Breast ultrasound: automated or hand-held? Exploring patients’ experience and preference. Eur Radiol Exp. 2020 Feb 10;4(1):12.

Guo R, Lu G, Qin B, Fei B. Ultrasound Imaging Technologies for Breast Cancer Detection and Management: A Review. Ultrasound Med Biol. 2018 Jan;44(1):37- 70.

Tan T, Platel B, Twellmann T, van Schie G, Mus R, Grivegnée A, et al. Evaluation of the effect of computer-aided classification of benign and malignant lesions on reader performance in automated three-dimensional breast ultrasound. Acad Radiol. 2013 Nov;20(11):1381-8.

van Zelst JCM, Tan T, Clauser P, Domingo A, Dorrius MD, Drieling D, et al. Dedicated computer-aided detection software for automated 3D breast ultrasound; an efficient tool for the radiologist in supplemental screening of women with dense breasts. Eur Radiol. 2018 Jul;28(7):2996-3006.

Jiang Y, Inciardi MF, Edwards AV, Papaioannou J. Interpretation Time Using a Concurrent-Read Computer-Aided Detection System for Automated Breast Ultrasound in Breast Cancer Screening of Women With Dense Breast Tissue. AJR Am J Roentgenol. 2018 Aug;211(2):452-461.

COVER Automated Breast Ultrasound

Preuzimanja

Objavljeno

08.11.2022

Kako citirati

Žaja, Marija, i Tatjana Matijaš. 2022. „Automatizirani Pregled Dojke Ultrazvukom“. Radiološki Vjesnik 46 (2): 10-17. https://doi.org/10.55378/rv.46.2.2.

Slični članci

1-10 od 17

Također možete Započni napredno pretraživanje sličnosti za ovaj članak.

Najčitaniji članci istog autora / istih autora

1 2 > >>