Abstract

Radiology is one of the fastest growing branches of medicine, and precisely one of the devices that follows this development the fastest is the computerized tomography device. Scientists are most focused on research into improving the parameters of the X-ray tube and detector as the most important parts of this imaging modality. In addition to the detector with energy integration, which is widely used today as part of everyday clinical practice, the subject of research is also a Photon countng detector. The numerous virtues that stand out in the new type of detector are responsible for the general opinion that in the future this new technology will dominate CT devices in clinical practice, improving the acquisition of numerous diagnostic and interventional procedures. It is believed that this technology ushers radiology into a new era precisely with its improved spatial and contrast resolution, noise reduction and increase of contrast to noise ratio, but also with new possibilities such as simultaneous imaging of multiple contrast agents and multi-energy imaging. Improvements in the visibility of iodine contrast agent provide additional diagnostic possibilities and more accurate differentiation of benign and malignant suspected lesions. The significantly smaller pixel size on this detector offers an almost two-fold increase in spatial resolution, and thus an increase in radiation dose efficiency. The use of a detector with a photon counter is therefore also suitable for pediatric patients, and there is also a wide range of low-dose imaging options for the purpose of preventive cancer screening. Processes such as the material decomposition and spectral imaging are still in the research process, but have great potential to optimize future daily clinical practice. More work and published research results are needed, but surely this technology will one day make the work of radiologic technologists and radiologists easier.

References

Janković S, Mihanović F. Uvod u radiologiju. Split: Sveučilište u Splitu; 2014.

Janković S, Mihanović F, Punda A, Radović D, Barić A, Hrepić D. Radiološki uređaji i oprema u radiologiji, radioterapiji i nuklearnoj medicini. Split: Sveučilište u Splitu; 2015.

Liguori C, Frauenfelder G, Massaroni C, Saccomandi P, Giurazza F, Pitocco F, Marano R, Schena E. Emerging clinical applications of computed tomography. Medical Devices: Evidence and Research. 2015 Jun 5:265-78.

Sartoretti T, Wildberger JE, Flohr T, Alkadhi H. Photon-counting detector CT: early clinical experience review. The British Journal of Radiology. 2023 Feb;95:20220544.

https://www.health.harvard.edu/cancer/radiation-risk-from-medical-imaging (accessed on 5.9.2023.)

McCollough CH, Bushberg JT, Fletcher JG, Eckel LJ. Answers to common questions about the use and safety of CT scans. InMayo Clinic Proceedings 2015 Oct 1 (Vol. 90, No. 10, pp. 1380-1392). Elsevier.

Schlemmer HP. The Eye of the CT Scanner: The story of learning to see the invisible or from the fluorescent screen to the photon-counting detector. InRöFo-Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren 2021 Sep (Vol. 193, No. 09, pp. 1034-1049). Georg Thieme Verlag KG.

Tóth T, Hudák R. Computed tomography-its development, principle and image artifacts. Acta Mechanica Slovaca. 2013;17(4):40-7.

Nakamura Y, Higaki T, Kondo S, Kawashita I, Takahashi I, Awai K. An introduction to photon-counting detector CT (PCD CT) for radiologists. Japanese Journal of Radiology. 2023 Mar;41(3):266-82.

Wang AS, Pelc NJ. Spectral photon counting CT: Imaging algorithms and performance assessment. IEEE transactions on radiation and plasma medical sciences. 2020 Jul 7;5(4):453-64.

Willemink MJ, Persson M, Pourmorteza A, Pelc NJ, Fleischmann D. Photon-counting CT: technical principles and clinical prospects. Radiology. 2018 Nov;289(2):293-312.

Taguchi K, Iwanczyk JS. Vision 20/20: single photon counting x‐ray detectors in medical imaging. Medical physics. 2013 Oct;40(10):100901.

Rajendran K, Löbker C, Schon BS, Bateman CJ, Younis RA, de Ruiter NJ, Chernoglazov AI, Ramyar M, Hooper GJ, Butler AP, Woodfield TB. Quantitative imaging of excised osteoarthritic cartilage using spectral CT. European radiology. 2017 Jan;27:384-92.

Ji X, Zhang R, Chen GH, Li K. Task-driven optimization of the non-spectral mode of photon counting CT for intracranial hemorrhage assessment. Physics in Medicine & Biology. 2019 Oct 31;64(21):215014.

Yu Z, Leng S, Jorgensen SM, Li Z, Gutjahr R, Chen B, Halaweish AF, Kappler S, Yu L, Ritman EL, McCollough CH. Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array. Physics in Medicine & Biology. 2016 Feb 2;61(4):1572.

https://www.fda.gov/news-events/press-announcements/fda-clears-first-major-imaging-device-advancement-computed-tomography-nearly-decade (accessed on 7.9.2023.)

Hamann E, Koenig T, Zuber M, Cecilia A, Tyazhev A, Tolbanov O, Procz S, Fauler A, Baumbach T, Fiederle M. Performance of a Medipix3RX spectroscopic pixel detector with a high resistivity gallium arsenide sensor. IEEE transactions on medical imaging. 2014 Apr 14;34(3):707-15.

Leng S, Bruesewitz M, Tao S, Rajendran K, Halaweish AF, Campeau NG, Fletcher JG, McCollough CH. Photon-counting detector CT: system design and clinical applications of an emerging technology. Radiographics. 2019 May;39(3):729-43.

Liu X, Grönberg F, Sjölin M, Karlsson S, Danielsson M. Count rate performance of a silicon-strip detector for photon-counting spectral CT. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2016 Aug 11;827:102-6.

Leng S, Rajendran K, Gong H, Zhou W, Halaweish AF, Henning A, Kappler S, Baer M, Fletcher JG, McCollough CH. 150-μm spatial resolution using photon-counting detector computed tomography technology: technical performance and first patient images. Investigative radiology. 2018 Nov 1;53(11):655-62.

Esquivel A, Ferrero A, Mileto A, Baffour F, Horst K, Rajiah PS, Inoue A, Leng S, McCollough C, Fletcher JG. Photon-Counting Detector CT: Key Points Radiologists Should Know. Korean Journal of Radiology. 2022 Sep 1;23(9):854-65.

Leng S, Yu Z, Halaweish A, Kappler S, Hahn K, Henning A, Li Z, Lane J, Levin DL, Jorgensen S, Ritman E. Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system. Journal of Medical Imaging. 2016 Oct 1;3(4):043504-.

Zhou W, Lane JI, Carlson ML, Bruesewitz MR, Witte RJ, Koeller KK, Eckel LJ, Carter RE, McCollough CH, Leng S. Comparison of a photon-counting-detector CT with an energy-integrating-detector CT for temporal bone imaging: a cadaveric study. American Journal of Neuroradiology. 2018 Sep 1;39(9):1733-8.

Duan X, Wang J, Leng S, Schmidt B, Allmendinger T, Grant K, Flohr T, McCollough CH. Electronic noise in CT detectors: impact on image noise and artifacts. American Journal of Roentgenology. 2013 Oct;201(4):W626-32.

Liu Y, Leng S, Michalak GJ, Vrieze TJ, Duan X, Qu M, Shiung MM, McCollough CH, Fletcher JG. Reducing image noise in computed tomography (CT) colonography: effect of an integrated circuit CT detector. Journal of computer assisted tomography. 2014 May 1;38(3):398-403.

Higashigaito K, Mergen V, Eberhard M, Jungblut L, Hebeisen M, Rätzer S, Zanini B, Kobe A, Martini K, Euler A, Alkadhi H. CT angiography of the aorta using photon-counting detector CT with reduced contrast media volume. Radiology: Cardiothoracic Imaging. 2023 Jan 26;5(1):e220140.

Baek J, Pineda AR, Pelc NJ. To bin or not to bin? The effect of CT system limiting resolution on noise and detectability. Physics in Medicine & Biology. 2013 Feb 11;58(5):1433.

Gutjahr R, Halaweish AF, Yu Z, Leng S, Yu L, Li Z, Jorgensen SM, Ritman EL, Kappler S, McCollough CH. Human imaging with photon-counting-based CT at clinical dose levels: Contrast-to-noise ratio and cadaver studies. Investigative radiology. 2016 Jul;51(7):421.

Chen H, Xu C, Persson M, Danielsson M. Optimization of beam quality for photon-counting spectral computed tomography in head imaging: simulation study. Journal of Medical Imaging. 2015 Oct 1;2(4):043504-.

Rajendran K, Voss BA, Zhou W, Tao S, DeLone DR, Lane JI, Weaver JM, Carlson ML, Fletcher JG, McCollough CH, Leng S. Dose reduction for sinus and temporal bone imaging using photon-counting detector CT with an additional tin filter. Investigative radiology. 2020 Feb;55(2):91.

Bennett JR, Opie AM, Xu Q, Yu H, Walsh M, Butler A, Butler P, Cao G, Mohs A, Wang G. Hybrid spectral micro-CT: system design, implementation, and preliminary results. IEEE transactions on biomedical engineering. 2013 Aug 26;61(2):246-53.

Shikhaliev PM. Soft tissue imaging with photon counting spectroscopic CT. Physics in Medicine & Biology. 2015 Mar 5;60(6):2453.

Silkwood JD, Matthews KL, Shikhaliev PM. Photon counting spectral breast CT: effect of adaptive filtration on CT numbers, noise, and contrast to noise ratio. Medical physics. 2013 May;40(5):051905.

Iyer VR, Ehman EC, Khandelwal A, Wells ML, Lee YS, Weber NM, Johnson MP, Yu L, McCollough CH, Fletcher JG. Image quality in abdominal CT using an iodine contrast reduction algorithm employing patient size and weight and low kV CT technique. Acta Radiologica. 2020 Sep;61(9):1186-95.

Hsieh SS, Leng S, Rajendran K, Tao S, McCollough CH. Photon counting CT: clinical applications and future developments. IEEE transactions on radiation and plasma medical sciences. 2020 Aug 28;5(4):441-52.

McCollough CH, Leng S, Yu L, Fletcher JG. Dual-and multi-energy CT: principles, technical approaches, and clinical applications. Radiology. 2015 Sep;276(3):637-53.

Kalisz K, Halliburton S, Abbara S, Leipsic JA, Albrecht MH, Schoepf UJ, Rajiah P. Update on cardiovascular applications of multienergy CT. Radiographics. 2017 Nov;37(7):1955-74.

Zhou W, Bartlett DJ, Diehn FE, Glazebrook KN, Kotsenas AL, Carter RE, Fletcher JG, McCollough CH, Leng S. Reduction of metal artifacts and improvement in dose efficiency using photon counting detector CT and tin filtration. Investigative radiology. 2019 Apr;54(4):204.

Koons E, VanMeter PD, Rajendran K, Yu L, McCollough C, Leng S. Improved assessment of coronary artery luminal stenosis with heavy calcifications using high-resolution photon-counting detector CT. InMedical Imaging 2022: Physics of Medical Imaging 2022 Apr 4 (Vol. 12031, pp. 319-323). SPIE.

Touch M, Clark DP, Barber W, Badea CT. A neural network-based method for spectral distortion correction in photon counting x-ray CT. Physics in Medicine & Biology. 2016 Jul 29;61(16):6132.

Jenkins P, Schmidt TG. Experimental study of neural network material decomposition to account for pulse-pileup effects in photon-counting spectral CT. InMedical Imaging 2019: Physics of Medical Imaging 2019 Mar 1 (Vol. 10948, pp. 498-503). SPIE.

Lu Y, Kowarschik M, Huang X, Chen S, Ren Q, Fahrig R, Hornegger J, Maier A. Material decomposition using ensemble learning for spectral X-ray imaging. IEEE Transactions on Radiation and Plasma Medical Sciences. 2018 Feb 12;2(3):194-204.

Hornegger J, Maier A. A learning‐based material decomposition pipeline for multi‐energy x‐ray imaging. Medical physics. 2019 Feb;46(2):689-703.

Zimmerman KC, Sharma G, Parchur AK, Joshi A, Schmidt TG. Experimental investigation of neural network estimator and transfer learning techniques for K‐edge spectral CT imaging. Medical physics. 2020 Feb;47(2):541-51.

Mimica P. CT detektor s brojačem fotona (Završni rad). Split: Sveučilište u Splitu, Sveučilišni odjel zdravstvenih studija; 2023 (pristupljeno 5.9.2023.) Available at: https://repo.ozs.unist.hr/islandora/object/ozs%3A1412

COVER Characteristics of the new Photon counting CT detector

Downloads

Published

2023-05-16

How to Cite

Mimica, Petra, and Tatjana Matijas. 2023. “Characteristics of the New Photon Counting CT Detector”. Radiological Journal 47 (2): 18-26. https://doi.org/10.55378/rv.47.2.3.

Similar Articles

11-15 of 15

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)

1 2 > >>