Abstract

There is significant increase in the use of x-ray imaging in medicine and still insufficient knowledge about effect of low radiation doses and how it is related with the incidence of cancer. Therefore, the optimization of diagnostic and interventional procedures plays an important role in radiation protection during medical imaging. The optimization process does not only refer to the adjustment of imaging protocol parameters, but encompasses a number of activities and professions involved in the process. Physician, radiographer and medical physicist are essential and irreplaceable in the optimization process, therefore it is important that the topic of optimization is included in part of their education and further training. Since quality assurance program prescribes activities such as quality control, image rejection analysis, recording of patient doses, calculation of typical values and comparison with diagnostic reference levels, its establishment is a necessary step in optimization. In recent years, application of artificial intelligence in optimization process is also important. Taking into account all these steps, the main goal of comprehensive optimization process is to achieve image quality that is adequate to answer the clinical question with minimal patient exposure.

References

European Commission. Report on Radiation Protection N° 180. Medical Radiation Exposure of the European Population, Part 1/2. European Commission, Brussels, 2014.

United Nations Scientific Committee on the Effects of Atomic Radiation. UNSCEAR 2020/2021 Report, Annex A – Evaluation of medical exposure to ionizing radiation. United Nations, New York, 2022.

International Atomic Energy Agency. Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards, IAEA Safety Standard Series No. GSR Part 3, No. GSR Part 3, IAEA, Vienna, 2014.

European Council Directive 97/43/Euratom on health protection of individuals against the dangers of ionizing radiation in relation to medical exposure and repealing Directive 84/466/Euratom. Official Journal of the European Communities, L 180; 22-27. 1997.

Kralik I, Buinac A, Justic M, Ružić K, Faj D. DRL – alat u službi optimizacije provedbe dijagnostičkih i intervencijskih postupaka. Radiološki Vjesnik, 2021; 2:16–19.

Kralik I, Bjelobrk I, Buinac A, Cvetko D, Justic M, Meštrić D, Popić J, Ružić K, Turk T, Faj D. Indikacijske vs. anatomske dijagnostičke referentne razine. Radiološki Vjesnik, 2023; 2:67–71.

Ministarstvo unutarnjih poslova. Pravilnik o uvjetima za primjenu izvora ionizirajućeg zračenja u svrhu medicinskog i nemedicinskog ozračenja. Nar novine 42/18, 8/22. 2022.

ICRP. Diagnostic reference levels in medical imaging. ICRP Publ 135. 2017; 46(1).

European Commission, Directorate-General for Research and Innovation, European guidelines on quality criteria for diagnostic radiographic images. Publications Office; 1996.

European Commission, Directorate-General for Research and Innovation, European guidelines on quality criteria for diagnostic radiographic images in paediatrics. Publications Office; 1996.

European Commission, Directorate-General for Research and Innovation, European guidelines on quality criteria for computed tomography. Publications Office; 1996.

Faulkner K. The DIMOND project and its impact on radiation protection. Radiation Protection Dosimetry. 2005;117(1-3):3-6.

Moore QT, Don S, Goske MJ, Strauss KJ, Cohen M, Herrmann T, Macdougall R, Noble L, Morrison G, John SD, Lehman L. Image gently: using exposure indicators to improve pediatric digital radiography. Radiol Technol. 2012; 84(1):93-9.

World Health Organization. Quality Assurance in Diagnostic Radiology. WHO, Geneva, 1982.

Ministarstvo unutarnjih poslova. Pravilnik o uvjetima i mjerama zaštite od ionizirajućeg zračenja za obavljanje djelatnosti s izvorima ionizirajućeg zračenja. Narodne novine 53/18, 6/22, 2022.

International Atomic Energy Agency, Handbook of Basic Quality Control Tests for Diagnostic Radiology. IAEA Human Health Series No. 47, IAEA, Vienna, 2023.

Hiles P, Gilligan P, Damilakis J et al. European consensus on patient contact shielding. Insights Imaging, 2021, 12:194.

Pierre K, Haneberg AG, Kwak S, Peters K, Hochhegger B, Sananmuang T, et al. Applications of artificial intelligence in the radiology roundtrip: process streamlining, workflow optimization, and beyond. Seminars in Roentgenology, 2023;58(2):158–69.

McCollough CH, Leng S. Use of artificial intelligence in computed tomography dose optimisation. Annals of the ICRP, 2020;49(1):113–25.

International Atomic Energy Agency, Artificial Intelligence in Medical Physics, Training Course Series No. 83, IAEA, Vienna, 2023.

Brady AP, Allen B, Chong J, Kotter E, Kottler N, Mongan J, et al. Developing, purchasing, implementing and monitoring AI tools in radiology: practical considerations. A multi-society statement from the ACR, CAR, ESR, RANZCR & RSNA. Insights Into Imaging, 2024;15(1).

COVER Optimizacija dijagnostičkih i intervencijskih postupaka koji se provode uporabom rendgenskih uređaja

Published

2024-05-08

How to Cite

Ruzic, Katarina, Ana Buinac, Mihaela Justic, Ivana Kralik, Ivana Bjelobrk, and Dario Faj. 2024. “Optimization of Diagnostic and Interventional Procedures”. Radiological Journal 48 (1): 39-45. https://doi.org/10.55378/rv.48.1.6.

Similar Articles

1-10 of 58

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)