Abstract

In continental lowland forests, an increase in the poor health status of ash trees has been observed in recent years. This study investigated the capabilities of modern radiological equipment for the cross-sectional imaging of tree trunks, specifically to determine whether a medical radiological device can visualize ash tree disease. Since a comparison of the performed radiological tomographic scans and existing photographs of the same samples showed that the changes visible on the photographs could also be seen on the radiographic images, the aim of this research was achieved. This confirms that the use of appropriate radiological equipment is satisfactory for the detection of changes caused by infectious diseases or other issues in ash trees.

References

D. Diminić, J. Kranjčec Orlović, Bolesti poljskog Jasena, Poljski Jasen u Hrvatskoj, Akademija šumarskih znanosti, CIP 001139257, ISBN 978-953-98571-7-0, Zagreb 2022.

A. Uldry, B. P. Husted, I. Pope, L. M. Ottosen: A Review of the Applicability of Non-destructive Testing for the Determination of the Fire Performance of Reused Structural Timber, Open access, Published: 21 September 2024, Volume 43, article number 106, (2024)

P. WITOMSKI, A. KRAJEWSKI, T. NAROJEK, Measurements of wood density using X-ray computer tomography, Faculty of Wood Technology, Warsaw University of Life Scieces – SGGW (WULS-SGGW)

Jacobs, P., Sevens, E., and Kunnen, M. (1995). “Principles of computerized X-ray tomography and applications to building materials,” The Science of the Total Environment 167(1-3), 161-170.

Livingston, R. A. (1999). “Nondestructive testing of historic structures,” Archives and Museum Informatics 13(3-4), 249-271.

Ge, Z. D., Hou, X. P., Li, Z. F., and Zhou, Y. C. (2016). “Application of computed tomography (CT) in nondestructive testing of wood,” China Wood Industry 30(3), 49-52.

Kovalisko, B. (2024), „Validacija sive skale na C-Luku u korelaciji s HU na CT-u “(Diplomski rad). Split: Sveučilište u Splitu. Available at: https://urn.nsk.hr/urn:nbn:hr:176:250840

C. E. Carter, B. L. Vealé, „Digital Radiography and PACS “, Book ISBN: 978-0-323547581,

Mackin D, Fave X, Zhang L, Yang J, Jones AK, Ng CS, and others, Harmonizing the pixel size in retrospective computed tomography radiomics studies, PLoS One. 2018 Jan 17;13(1): e0191597. eCollection 2018, PMID: 29342209.

Review of Trees Using Medical Radiological Equipment

Downloads

Published

2025-11-04

Issue

Section

Original scientific papers

How to Cite

Ciprić, Damir, Velimir Karadza, Vladimir Kusan, Frane Mihanovic, and Branko Kovalisko. 2025. “Review of Trees Using Medical Radiological Equipment”. Radiological Journal 49 (2): 10-16. https://doi.org/10.55378/rv.49.2.2.

Similar Articles

1-10 of 64

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)

<< < 1 2