The utilization of a handheld X-ray device for intraoral imaging in modern dental practice
DOI:
https://doi.org/10.55378/rv.48.1.5Keywords:
handheld, NOMAD, Heliodent, intraoral, dentistry, radiographyAbstract
Recently, there has been an increased interest in the utilization of a handheld X-ray devices for intraoral imaging in modern dental practice. Globally, several documents with recommended guidelines on the utilization of a handheld X-ray device for intraoral imaging have been issued. Considering that the recommended guidelines were contradictory, additional research was initiated on the justification of manual utilization in everyday practice. The goal of this article is to present the justification for the utilization of a handheld X-ray devices as an alternative to wall mounted fixed devices that has been presented by several studies that examined the level of radiation received by the operator, the environment and the patient. In the interest of research, the emphasis was also on the radiological image quality control. Although the results of the quality parameters on the radiological image with both types of devices proved to be successful, the results of the radiation dose oscillated and were not completely acceptable for the operator, the environment and the patient, if all radiation protection guidelines were not followed. Further research should be done additionally on people, instead on models and phantoms, before they are fully introduced into everyday dental practice.
References
Nitschke J, Schorn L, Holtmann H, Zeller U, Handschel J, Sonntag D, Lommen J. Image quality of a portable X-ray device (Nomad Pro 2) compared to a wall mounted device in intraoral radiography. Oral Radiol. 2021 Apr;37(2):224-230. doi: 10.1007/s11282-020-00434-1.
Geist, J. R. (2021). Handheld intraoral dental x-ray devices should supplement but not replace conventional radiographic equipment. Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 132(3), 257–259. doi:10.1016/j.oooo.2021.06.001
W E R Berkhout, A Suomalainen, D Brüllmann, R Jacobs, K Horner, H C Stamatakis, Justification and good practice in using handheld portable dental X-ray equipment: a position paper prepared by the European Academy of DentoMaxilloFacial Radiology (EADMFR), Dentomaxillofacial Radiology, Volume 44, Issue 6, 1 July 2015, 20140343, https://doi.org/10.1259/dmfr.20140343
D N S V, Ramesh; Wale, Mahalakshmi; Thriveni, R.; Byatnal, Amit. Handheld X-ray device: A review. Journal of Indian Academy of Oral Medicine and Radiology 30(2):p 153-157, Apr–Jun 2018. | DOI: 10.4103/jiaomr.jiaomr_36_18
Handheld vs. conventional wall mounted x-ray units [Internet] [accessed 07.03.2024.] Available at: https://www.rdhmag.com/patient-care/article/14068492/handheld-vs- conventional-wall mounted-x-ray-units
Rottke D, Gohlke L, Schrödel R, Hassfeld S, Schulze D. Operator safety during the acquisition of intraoral images with a handheld and portable X-ray device. Dentomaxillofac Radiol. 2018 Feb;47(3):20160410. doi: 10.1259/dmfr.20160410.
Patel, J. Rectangular collimators. Br Dent J 235, 669 (2023). https://doi.org/10.1038/s41415-023-6508-z
Otaka Y, Harata Y, Izawa M, Shiba N, Iwawaki A, Ishii T, Ochiai A, Takahashi N, Saka H, Kito S. Stray radiation dose reduction using a backscatter shield and a rectangular collimator for a handheld intraoral X-ray unit. Radiat Prot Dosimetry. 2023 Nov 16;199(19):2349-2355. doi: 10.1093/rpd/ncad239.
A Cc Gonzales, M R Soares, W O G Batista, A R Cardeña, J P Marquez, J R Vega, Application of the monte carlo method for the evaluation of scattered radiation dose due to the utilization of handheld x-ray in dentistry, Radiation Protection Dosimetry, Volume 198, Issue 16, September 2022, Pages 1210–1218, https://doi.org/10.1093/rpd/ncac156
Makdissi J, Pawar RR, Johnson B, Chong BS. The effects of device position on the operator’s radiation dose when using a handheld portable X-ray device. Dentomaxillofac Radiol. 2016;45(3):20150245. doi: 10.1259/dmfr.20150245.
Lommen J, Schorn L, Nitschke J, Sproll C, Zeller U, Kübler NR, Handschel J, Holtmann H. Accuracy in positioning of dental X-ray images – A comparative study of a portable X-ray device and a wall mounted device. Saudi Dent J. 2021 Dec;33(8):884-889. doi: 10.1016/j.sdentj.2021.09.018.
Pittayapat, P., Oliveira-Santos, C., Thevissen, P., Michielsen, K., Bergans, N., Willems, G., ... Jacobs, R. (2010). Image quality assessment and medical physics evaluation of different portable dental X-ray units. Forensic Science International, 201(1-3), 112–117. doi:10.1016/j.forsciint.2010.04.041
Downloads
Published
Issue
Section
Categories
License
Copyright (c) 2024 Anita Ivanovic (Author)

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
CART