Radiation protection in MSCT diagnostics: A systematic literature review

Authors

  • Franciska Canaki Opća bolnica “ Dr. Tomislav Bardek” Koprivnica, Koprivnica , Sveučilište u Splitu, Sveučilišni odjel zdravstvenih studija, Split Author
  • Kresimir Dolic Sveučilište u Splitu, Sveučilišni odjel zdravstvenih studija, Split , Klinički bolnički centar Split, Split Author

DOI:

https://doi.org/10.55378/rv.47.2.6

Keywords:

radiation protection, MSCT, biological effects of ionizing radiation, patient safety, techniques for dose reduction

Abstract

The systematic literature review “Radiation protection in MSCT diagnostics” analyses the accepted and established methods, while emphasizing modern methods of radiation protection in the field of Multi-Slice Computed Tomography (MSCT).

The aim of the article is to familiarize the reader with: the basic terms related to radiation protection; the biological impact of ionizing radiation delivered to the human body during MSCT examination and measurement of its levels; the parameters that affect the reduction (or due to improper use, increase) of the radiation dose, and the ways in which proper adaptation of these parameters can significantly influence the radiation exposure of the patient during the MSCT examination; and summarize the most important findings regarding the optimization of radiation protection and the various techniques for achieving it. This article can serve as a reminder of the basic concepts and the importance of conscientious implementation of radiation protection measures in everyday practice for healthcare workers who participate in the implementation of MSCT diagnostic procedures.

References

McCollough C, Bakalyar DM, Bostani M, et al. Use of Water Equivalent Diameter for Calculating Patient Size and Size-Specific Dose Estimates (SSDE) in CT: The Report of AAPM Task Group 220. AAPM Rep. 2014 Sep; 2014:6-23.

Turner AC, Zankl M, DeMarco JJ, et al. The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: using CTDI vol to account for differences between scanners. Med Phys. 2010 Apr; 37(4):1816-25.

Boone J, Strauss K, Cody D, et al. Size-specific dose estimates (SSDE) in pediatric and adult body CT exams: Report of AAPM Task Group 204, 2011.

Gnannt R, Winklehner A, Eberli D, Knuth A, Frauenfelder T, Alkadhi H. Automated tube potential selection for standard chest and abdominal CT in follow-up patients with testicular cancer: comparison with fixed tube potential. Eur Radiol. 2012;22(9):1937-1945.

Alsafi KG. Radiation Protection in X-Ray Computed Tomography: Literature Review. Int J Radiol Imaging Technol 2:016, 2016.

Vañó E, Miller DL, Martin CJ, et al. ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging. Ann ICRP. 2017;46(1):1-144..

Paul JF. Individually adapted coronary 64-slice CT angiography based on precontrast attenuation values, using different kVp and tube current settings: evaluation of image quality. Int J Cardiovasc Imaging. 2011;27 Suppl 1:53-59..

Papadakis AE, Damilakis J. Evaluation of an organ-based tube current modulation tool in pediatric CT examinations. Eur Radiol. 2020;30(10):5728-5737.

Guberina N, Lechel U, Forsting M, Ringelstein A. Efficacy of high-pitch CT protocols for radiation dose reduction. J Radiol Prot. 2016;36(4):N57-N66..

Goldman LW. Principles of CT: multislice CT. J Nucl Med Technol. 2008;36(2):57-76.

Raman SP, Mahesh M, Blasko RV, Fishman EK. CT scan parameters and radiation dose: practical advice for radiologists. J Am Coll Radiol. 2013;10(11):840-846.

McNitt-Gray M,. Radiation safety in CT. A virtual symposium. University of California, San Francisco May 8-10.2013.

ICRP, 2007. Managing Patient Dose in Multi-Detector Computed Tomography (MDCT). ICRP Publication 102. Ann. ICRP 37 (1)

Urikura A, Hara T, Yoshida T, et al. Overranging and overbeaming measurement in area detector computed tomography: A method for simultaneous measurement in volume helical acquisition. J Appl Clin Med Phys. 2019;20(7):160-165.

ICRP, 2007. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann. ICRP 37 (2-4)

Schilham A, van der Molen AJ, Prokop M, de Jong HW. Overranging at multisection CT: an underestimated source of excess radiation exposure. Radiographics. 2010;30(4):1057-1067.

Booij R, Dijkshoorn ML, van Straten M. Efficacy of a dynamic collimator for overranging dose reduction in a second- and third-generation dual source CT scanner. Eur Radiol. 2017; 27(9):3618-3624.

Deak PD, Langner O, Lell M, Kalender WA. Effects of adaptive section collimation on patient radiation dose in multisection spiral CT. Radiology. 2009;252(1):140-147.

Li J, Udayasankar UK, Toth TL, Seamans J, Small WC, Kalra MK. Automatic patient centering for MDCT: effect on radiation dose. AJR Am J Roentgenol. 2007; 188(2):547-552.

Habibzadeh MA, Ay MR, Asl AR, Ghadiri H, Zaidi H. Impact of miscentering on patient dose and image noise in x-ray CT imaging: phantom and clinical studies. Phys Med. 2012; 28(3):191-199.

Hsieh J, SPIE (Society). Computed Tomography: Principles Design Artifacts and Recent Advances. 2nd ed. Wiley Interscience ; SPIE Press 2009.

Singh S, Kalra MK, Hsieh J, et al. Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques. Radiology. 2010; 257(2):373-383.

Singh S, Kalra MK, Gilman MD, et al. Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study. Radiology. 2011; 259(2):565-573.

Padole A, Ali Khawaja RD, Kalra MK, Singh S. CT radiation dose and iterative reconstruction techniques. AJR Am J Roentgenol. 2015; 204(4):W384-W392

International Atomic Energy Agency, Quality Assurance Programme for Computed Tomography: Diagnostic and Therapy Applications, Human Health Series No. 19, IAEA, Vienna; 2012.

Marsh RM, Silosky M. Patient Shielding in Diagnostic Imaging: Discontinuing a Legacy Practice. AJR Am J Roentgenol. 2019;212(4):755-757.

Marsh RM, Silosky M. Patient Shielding in Diagnostic Imaging: Discontinuing a Legacy Practice. AJR Am J Roentgenol. 2019 Apr;212(4):755-757. doi: 10.2214/AJR.18.20508. Epub 2019 Jan 23. PMID: 30673332.

COVER Zaštita od zračenja kod MSCT pretraga: Sustavni pregled literature

Published

2023-05-16

How to Cite

Canaki, Franciska, and Kresimir Dolic. 2023. “Radiation Protection in MSCT Diagnostics: A Systematic Literature Review”. Radiological Journal 47 (2): 46-51. https://doi.org/10.55378/rv.47.2.6.

Similar Articles

11-20 of 60

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)