Dual-energy CT in polytrauma
Protocol implementation and radiation dose reduction at University Hospital Centre Zagreb
DOI:
https://doi.org/10.55378/rv.50.1.3Keywords:
polytrauma, computed tomography, dual-energy CT, split-bolus, virtual non-contrast, radiation dose, dose-length product (DLP)Abstract
Aim: To evaluate dual-energy CT (DECT) whole-body polytrauma protocols and quantify radiation dose reduction compared with a standard multiphase CT protocol.
Materials and Methods: This retrospective single-centre study included polytrauma patients, stratified into three groups: standard CT (n = 255), DECT-stable (n = 164), and DECT-unstable (n = 19). Radiation dose was assessed using the dose-length product (DLP).
Results: Median DLP was 5940 mGy·cm (standard), 2671 mGy·cm (DECT stable), and 3247.5 mGy·cm (DECT unstable), corresponding to dose reductions of 55.0% and 45.3%, respectively.
Conclusion: DECT protocols enable substantial radiation dose reduction while maintaining clinical workflow efficiency.
References
Wirth S, Hebebrand J, Basilico R, et al. European Society of Emergency Radiology guideline on radiological polytrauma imaging. Insights Imaging. 2020;11:135. DOI:10.1186/s13244-020-00947-7.
Flammia F, Chiti G, Trinci M, et al. Optimization of CT protocol in polytrauma patients. Eur Rev Med Pharmacol Sci. 2022;26:2543–2555.
Borges AP, Antunes C, Curvo-Semedo L, et al. Pros and cons of dual-energy CT systems. Tomography. 2023;9(1):195–216., DOI:10.3390/tomography9010017.
Booz C, Hofmann PC, Martin SS, et al. Radiation dose reduction in dual-energy CT trauma imaging. Eur J Radiol. 2019;117:27–33, DOI: 10.1007/s00330-019-06357-2
McCollough CH, Leng S, Yu L, Fletcher JG. Dual- and multi-energy CT. Radiology. 2015;276:637–653, DOI: 10.1148/radiol.2015142631
Aran, S., Shaqdan, K.W. & Abujudeh, H.H. Dual-energy computed tomography (DECT) in emergency radiology: basic principles, techniques, and limitations. Emerg Radiol 21, 391–405 (2014). https://doi.org/10.1007/s10140-014-1208-2
Wortman JR, Uyeda JW, Fulwadhva UP, Sodickson AD. Dual-Energy CT for Abdominal and Pelvic Trauma. RadioGraphics. 2018;38(2):586-602, DOI: 10.1148/rg.2018170058
Euler A, Parakh A, Falkowski AL, et al. Initial experience with dual-energy CT in polytrauma: diagnostic performance and added value. European Radiology. 2019;29(9):4763–4772. doi:10.1007/s00330-019-06047-1.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Alen Udovičić, Bepo Vasić, Marijana Pervan (Autor)

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
CART