Dual-energy CT in polytrauma

Protocol implementation and radiation dose reduction at University Hospital Centre Zagreb

Authors

  • Alen Udovicic Department of Radiology, University Hospital Centre Zagreb, Croatia Author
  • Bepo Vasic Department of Radiology, University Hospital Centre Zagreb, Croatia Author
  • Marijana Pervan Department of Radiology, University Hospital Centre Zagreb, Croatia Author

DOI:

https://doi.org/10.55378/rv.50.1.3

Keywords:

polytrauma, computed tomography, dual-energy CT, split-bolus, virtual non-contrast, radiation dose, dose-length product (DLP)

Abstract

Aim: To evaluate dual-energy CT (DECT) whole-body polytrauma protocols and quantify radiation dose reduction compared with a standard multiphase CT protocol.
Materials and Methods: This retrospective single-centre study included polytrauma patients, stratified into three groups: standard CT (n = 255), DECT-stable (n = 164), and DECT-unstable (n = 19). Radiation dose was assessed using the dose-length product (DLP).
Results: Median DLP was 5940 mGy·cm (standard), 2671 mGy·cm (DECT stable), and 3247.5 mGy·cm (DECT unstable), corresponding to dose reductions of 55.0% and 45.3%, respectively.
Conclusion: DECT protocols enable substantial radiation dose reduction while maintaining clinical workflow efficiency.

References

Wirth S, Hebebrand J, Basilico R, et al. European Society of Emergency Radiology guideline on radiological polytrauma imaging. Insights Imaging. 2020;11:135. DOI:10.1186/s13244-020-00947-7.

Flammia F, Chiti G, Trinci M, et al. Optimization of CT protocol in polytrauma patients. Eur Rev Med Pharmacol Sci. 2022;26:2543–2555.

Borges AP, Antunes C, Curvo-Semedo L, et al. Pros and cons of dual-energy CT systems. Tomography. 2023;9(1):195–216., DOI:10.3390/tomography9010017.

Booz C, Hofmann PC, Martin SS, et al. Radiation dose reduction in dual-energy CT trauma imaging. Eur J Radiol. 2019;117:27–33, DOI: 10.1007/s00330-019-06357-2

McCollough CH, Leng S, Yu L, Fletcher JG. Dual- and multi-energy CT. Radiology. 2015;276:637–653, DOI: 10.1148/radiol.2015142631

Aran, S., Shaqdan, K.W. & Abujudeh, H.H. Dual-energy computed tomography (DECT) in emergency radiology: basic principles, techniques, and limitations. Emerg Radiol 21, 391–405 (2014). https://doi.org/10.1007/s10140-014-1208-2

Wortman JR, Uyeda JW, Fulwadhva UP, Sodickson AD. Dual-Energy CT for Abdominal and Pelvic Trauma. RadioGraphics. 2018;38(2):586-602, DOI: 10.1148/rg.2018170058

Euler A, Parakh A, Falkowski AL, et al. Initial experience with dual-energy CT in polytrauma: diagnostic performance and added value. European Radiology. 2019;29(9):4763–4772. doi:10.1007/s00330-019-06047-1.

Naslovnica Dvoenergetska CT dijagnostika u politraumi

Downloads

Published

2026-05-05

Issue

Section

Original scientific papers

How to Cite

Udovicic, Alen, Bepo Vasic, and Marijana Pervan. 2026. “Dual-Energy CT in Polytrauma: Protocol Implementation and Radiation Dose Reduction at University Hospital Centre Zagreb”. Radiological Journal 50 (1): 13-16. https://doi.org/10.55378/rv.50.1.3.

Similar Articles

1-10 of 54

You may also start an advanced similarity search for this article.