Automated Breast Ultrasound

Authors

  • Marija Zaja University of Split, University Department of Health Studies, Split, Croatia Author
  • Tatjana Matijas University of Split, University Department of Health Studies, Split, Croatia Author

DOI:

https://doi.org/10.55378/rv.46.2.2

Keywords:

ABUS, breast cancer, CAD, mammography, screening

Abstract

Due to the growing number of breast cancer patients, an early diagnosis is important in order to reduce the mortality rate of those affected. Methods such as mammography, DBT, MRI, HHUS or ABUS are used in the detection of breast cancer. The aim of this article is to review the literature showing the basic principle of ABUS and to point out its advantages and disadvantages in relation to conventional methods of breast imaging. ABUS is a relatively new ultrasound method that performs well on patients with dense breast tissue. It reduces operator dependence and provides valuable diagnostic information with multiplanar reconstructions. Using evidence from reliable researches, studies have demonstrated that ABUS has a higher diagnostic accuracy compared to mammography, which remains the primary modality for early diagnosis of breast cancer. Applying ABUS as an adjunct to mammography during the screening test has proven effective and further confirmed the importance of their application in clinical practice. The disadvantage of the combination of ABUS and mammography was that in a large number of studies the specificity was lower compared to mammography itself. Compared to DBT, ABUS has demonstrated to have a higher diagnostic performance, with the exception that it lacks the ability to effectively detect calcifications. Although MRI seem to outperform ABUS, ABUS devices offer a cost-effective and easy to use imaging system, making it the best alternative. The HHUS technique, on the other hand, was perceived by many studies as less painful, with a shorter operative time compared to ABUS. However, the sensitivity and specificity of this screening method continues to remain inferior to ABUS. The use of artificial intelligence is becoming widely used today. As a result, the CAD software has been developed to be applied in conjunction with ABUS in order to improve the detection rate of breast cancer as well as its accuracy. The use of CAD significantly reduced image reading time and improved the overall diagnostic accuracy of ABUS. According to all the presented data, the use of ABUS medical devices in clinical practice continues to grow in importance and with the further development of technology and medicine, its full integration into healthcare systems around the world is expected.

References

ˮBreast cancerˮ [Internet]. World Health Organization, 26 March 2021, [accessed: 13.5.2022].

Available at: https://www.who.int/news-room/fact-sheets/detail/breast-cancer

ˮIncidencija i mortalitet od raka u EU-27 zemljama za 2020. godinuˮ [Internet]. Hzjz.hr, 3. rujna 2020, [accessed: 13.5.2022].

Available at: https://www.hzjz.hr/sluzba-epidemiologija-prevencija-nezaraznih- bolesti/incidencija-i-mortalitet-od-raka-u-eu-27-zemljama-za-2020-godinu/

Radović, N. Utjecaj radioterapije na vrijednost očiglednoga koeficijenta difuzije zdravoga tkiva i lezija dojke pri oslikavanju magnetskom rezonancijom. [Internet]. Zagreb, Sveučilište u Zagrebu, Medicinski fakultet; 2020, [accessed: 13.5.2022].

Available at: https://repozitorij.mef.unizg.hr/islandora/object/mef:2929

ˮRak dojkeˮ [Internet]. Hlpr.hr, [accessed: 13.5.2022].

Available at: https://hlpr.hr/rak/vijest/rak-dojke

ˮNacionalni programi ranog otkrivanja rakaˮ [Internet]. Hzjz.hr, 22. prosinca 2016, [accessed: 13.5.2022].

Available at: https://www.hzjz.hr/sluzba-epidemiologija-prevencija-nezaraznih-%20bolesti/preventivni-program-za-zdravlje-danas/#rak-dojke

Poljičak, D. Radiološka dijagnostika bolesti dojke. [Internet]. Split, Sveučilište u Splitu, Sveučilišni odjel zdravstvenih studija; 2018, [accessed: 13.5.2022].

Available at: https://repo.ozs.unist.hr/islandora/object/ozs:705

Zanotel M, Bednarova I, Londero V, Linda A, Lorenzon M, Girometti R, et al. Automated breast ultrasound: basic principles and emerging clinical applications. Radiol Med. 2018 Jan;123(1):1-12.

Boca Bene I, Ciurea AI, Ciortea CA, Dudea SM. Pros and Cons for Automated Breast Ultrasound (ABUS): A Narrative Review. J Pers Med. 2021 Jul 23;11(8):703.

ˮFDA Clears somo•V Automated Breast Ultrasound (ABUS) Systemˮ [Internet]. Itnonline.com, 2012, [accessed: 22.5.20022]

Available at: https://www.itnonline.com/content/fda-clears-somo%E2%80%A2v-automated- breast-ultrasound-abus-system

Jia M, Lin X, Zhou X, Yan H, Chen Y, Liu P, et al. Diagnostic performance of automated breast ultrasound and handheld ultrasound in women with dense breasts. Breast Cancer Res Treat. 2020 Jun;181(3):589-597.

Nicosia L, Ferrari F, Bozzini AC, Latronico A, Trentin C, Meneghetti L, et al. Automatic breast ultrasound: state of the art and future perspectives. Ecancermedicalscience. 2020 Jun 23;14:1062.

ˮInveniaTM ABUS 2.0ˮ [Internet]. Ge-ultrasound.eu, [accessed: 22.5.2022]

Available at: https://ge-ultrasound.eu/voluson-gynecology-obstetrics/invenia-abus-2-%200/?gclid=CjwKCAiAg6yRBhBNEiwAeVyL0FcadAUlZ8rYLQIdMWhnI3qWz%20SCM0GVksIGOm7PKisANiodgLFyROBoCcp4QAvD_BwE

Mostafa AAE, Eltomey MA, Elaggan AM, Hashish AA. Automated breast ultrasound (ABUS) as a screening tool: initial experience. Egypt J Radiol Nucl Med. 2019;50, 37

Elkhalek YI, Bassiouny AM, Hamid RWARA. Automated breast ultrasound system (ABUS): can it replace mammography as a screening tool?. Egypt J Radiol Nucl Med. 2019;50, 51

Xin Y, Zhang X, Yang Y, Chen Y, Wang Y, Zhou X, Qiao Y. A multicenter, hospital-based and non-inferiority study for diagnostic efficacy of automated whole breast ultrasound for breast cancer in China. Sci Rep. 2021 Jul 6;11(1):13902

Hadadi I, Rae W, Clarke J, McEntee M, Ekpo E. Diagnostic Performance of Adjunctive Imaging Modalities Compared to Mammography Alone in Women with Non-Dense and Dense Breasts: A Systematic Review and Meta-Analysis. Clin Breast Cancer. 2021 Aug;21(4):278-291.

Giger ML, Inciardi MF, Edwards A, Papaioannou J, Drukker K, Jiang Y, et al. Automated Breast Ultrasound in Breast Cancer Screening of Women With Dense Breasts: Reader Study of Mammography-Negative and Mammography-Positive Cancers. AJR Am J Roentgenol. 2016 Jun;206(6):1341-50.

Wilczek B, Wilczek HE, Rasouliyan L, Leifland K. Adding 3D automated breast ultrasound to mammography screening in women with heterogeneously and extremely dense breasts: Report from a hospital-based, high-volume, single- center breast cancer screening program. Eur J Radiol. 2016 Sep;85(9):1554-63.

Gatta G, Cappabianca S, La Forgia D, Massafra R, Fanizzi A, Cuccurullo V, et al. Second-Generation 3D Automated Breast Ultrasonography (Prone ABUS) for Dense Breast Cancer Screening Integrated to Mammography: Effectiveness, Performance and Detection Rates. J Pers Med. 2021 Aug 31;11(9):875.

Zintsmaster S, Morrison J, Sharman S, Shah BA. Differences in Pain Perceptions between Automated Breast Ultrasound and Digital Screening Mammography. Journal of Diagnostic Medical Sonography. 2013;29(2):62-65.

Hashem LMB, Ali RHM, Helal MH, Gemeae EL, Moustafa AFI. Characterization of breast masses: a comparative study between automated breast ultrasound (ABUS) and digital breast tomosynthesis (DBT). Egypt J Radiol Nucl Med. 2020 Mar;51, 47

ˮABUS better than DBT for diagnostic workupˮ [Internet] Auntminnie.com, 2019, [accessed: 7.6.2022]

Available at: https://www.auntminnie.com/index.aspx?sec=404&sub=def

Schäfgen B, Juskic M, Radicke M, Hertel M, Barr R, Pfob A, et al. Evaluation of the FUSION-X-US-II prototype to combine automated breast ultrasound and tomosynthesis. Eur Radiol. 2021 Jun;31(6):3712-3720.

ˮFinal Report Summary – ASSURE (Adapting Breast Cancer Screening Strategy Using Personalised Risk Estimation)ˮ [Internet] Cordis.europa.eu, 2016, [accessed: 7.6.2022]

Available at: https://cordis.europa.eu/project/id/306088/reporting

Obdeijn IM, Winter-Warnars GA, Mann RM, Hooning MJ, Hunink MG, Tilanus- Linthorst MM. Should we screen BRCA1 mutation carriers only with MRI? A multicenter study. Breast Cancer Res Treat. 2014 Apr;144(3):577-82.

Obdeijn IM, Mann RM, Loo CCE, Lobbes M, Voormolen EMC, van Deurzen CHM, et al. The supplemental value of mammographic screening over breast MRI alone in BRCA2 mutation carriers. Breast Cancer Res Treat. 2020 Jun;181(3):581-588.

Giuliano V, Giuliano C. Using Automated Breast Sonography as Part of a Multimodality Approach to Dense Breast Screening. Journal of Diagnostic Medical Sonography. 2012;28(4):159-165.

Schmachtenberg C, Fischer T, Hamm B, Bick U. Diagnostic Performance of Automated Breast Volume Scanning (ABVS) Compared to Handheld Ultrasonography With Breast MRI as the Gold Standard. Acad Radiol. 2017 Aug;24(8):954-961.

Girometti R, Zanotel M, Londero V, Linda A, Lorenzon M, Zuiani C. Automated breast volume scanner (ABVS) in assessing breast cancer size: A comparison with conventional ultrasound and magnetic resonance imaging. Eur Radiol. 2018 Mar;28(3):1000-1008.

Kim SH, Kim HH, Moon WK. Automated Breast Ultrasound Screening for Dense Breasts. Korean J Radiol. 2020 Jan;21(1):15-24.

Zhang X, Chen J, Zhou Y, Mao F, Lin Y, Shen S, et al.. Diagnostic value of an automated breast volume scanner compared with a hand-held ultrasound: a metaanalysis. Gland Surg. 2019 Dec;8(6):698-711.

Yun G, Kim SM, Yun B, Ahn HS, Jang M. Reliability of automated versus handheld breast ultrasound examinations of suspicious breast masses. Ultrasonography. 2019 Jul;38(3):264-271.

Chen H, Han M, Jing H, Liu Z, Shang H, Wang Q, et al. Dependability of Automated Breast Ultrasound (ABUS) in Assessing Breast Imaging Reporting and Data System (BI-RADS) Category and Size of Malignant Breast Lesions Compared with Handheld Ultrasound (HHUS) and Mammography (MG). Int J Gen Med. 2021 Dec 1;14:9193-9202.

Jeh SK, Kim SH, Choi JJ, Jung SS, Choe BJ, Park S, et al. Comparison of automated breast ultrasonography to handheld ultrasonography in detecting and diagnosing breast lesions. Acta Radiol. 2016 Feb;57(2):162-9.

Allajbeu I, Hickman S, Payne N, Moyle P, Taylor K, Sharma N, et al. Automated Breast Ultrasound: Technical Aspects, Impact on Breast Screening, and Future Perspectives. Current Breast Cancer Reports. 2021 Jun;13(3):141-150.

Tutar B, Esen Icten G, Guldogan N, Kara H, Arıkan AE, Tutar O, et al. Comparison of automated versus hand-held breast US in supplemental screening in asymptomatic women with dense breasts: is there a difference regarding woman preference, lesion detection and lesion characterization? Arch Gynecol Obstet. 2020 May;301(5):1257-1265.

Brunetti N, De Giorgis S, Zawaideh J, Rossi F, Calabrese M, Tagliafico AS. Comparison between execution and reading time of 3D ABUS versus HHUS. Radiol Med. 2020 Dec;125(12):1243-1248.

Mussetto I, Gristina L, Schiaffino S, Tosto S, Raviola E, Calabrese M. Breast ultrasound: automated or hand-held? Exploring patients’ experience and preference. Eur Radiol Exp. 2020 Feb 10;4(1):12.

Guo R, Lu G, Qin B, Fei B. Ultrasound Imaging Technologies for Breast Cancer Detection and Management: A Review. Ultrasound Med Biol. 2018 Jan;44(1):37- 70.

Tan T, Platel B, Twellmann T, van Schie G, Mus R, Grivegnée A, et al. Evaluation of the effect of computer-aided classification of benign and malignant lesions on reader performance in automated three-dimensional breast ultrasound. Acad Radiol. 2013 Nov;20(11):1381-8.

van Zelst JCM, Tan T, Clauser P, Domingo A, Dorrius MD, Drieling D, et al. Dedicated computer-aided detection software for automated 3D breast ultrasound; an efficient tool for the radiologist in supplemental screening of women with dense breasts. Eur Radiol. 2018 Jul;28(7):2996-3006.

Jiang Y, Inciardi MF, Edwards AV, Papaioannou J. Interpretation Time Using a Concurrent-Read Computer-Aided Detection System for Automated Breast Ultrasound in Breast Cancer Screening of Women With Dense Breast Tissue. AJR Am J Roentgenol. 2018 Aug;211(2):452-461.

COVER Automated Breast Ultrasound

Published

2022-11-08

How to Cite

Zaja, Marija, and Tatjana Matijas. 2022. “Automated Breast Ultrasound”. Radiological Journal 46 (2): 10-17. https://doi.org/10.55378/rv.46.2.2.

Similar Articles

1-10 of 17

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)

1 2 > >>